OBSOLETE ›
Ce produit n'est plus disponible. Certains accessoires, pièces de rechange ou des services peuvent être encore disponibles.
ENVIROSCAN Water-Content-Profile Probe with SDI-12 Interface
Services disponibles

Aperçu

The EnviroSCAN probe provides soil-water-content profiles for irrigation scheduling or other water movement systems. The measurement range is oven dry to saturation. The probes measure soil moisture at multiple depths and are easy to install. Tools offered by Campbell Scientific allow the probes to be installed with minimal soil disturbance. EnviroSCAN is recommended for higher accuracy research measurements, measurements deeper than 80 cm, or stony soils. It is customizable by adding sensors at user-specified depths.

Lire la suite

Images

Description technique

The EnviroSMART probe has been renamed EnviroSCAN.

The EnviroSCAN includes several water content sensors that measure soil water at multiple depths. Around each sensor, the probe creates a high frequency electrical field that extends through the access tube into the soil. Electrical capacitance is then measured and soil water content is determined from those measurements.

Each water content sensor outputs an SDI-12 signal that our CR200(X)-series, CR800, CR850, CR1000, and CR3000 dataloggers can measure. This allows the probes to be integrated with a Campbell Scientific datalogger or weather station. Integrating the probes into our data acquisition systems allows the data to be telemetered back to a field station or remote computer.

EnviroSCAN is customized for individual applications by adding sensors at user-specified measurement depths. The maximum measurement depth of the standard configuration is 2 m (6 ft); deeper measurements are possible with special provisions.

Spécifications

Maximum Sensors per Standard Probe 16
Sensor Measuring Principle High-frequency capacitance
Sortie SDI-12 version 1.2
Water Content Reading Range 0 to ~65%
Temperature Effects ±3% (5° to 35°C)
Time to Read 1 Sensor 1.1 s
Sphere of Influence 99% of the reading is taken within a 10 cm radius from the outside of the access tube.
Température de fonctionnement -20° to +75°C
Diamètre du capteur 5.05 cm (2.0 in.)
Access Tube Diameter 5.65 cm (2.2 in.)
Longueur de la sonde 0.5, 1.0, 1.5, or 2.0 m (1.6, 3.3, 4.9, or 6.6 ft)

Compatibilité

Veuillez noter : Ce qui suit montre des informations de compatibilité générales. Ce n'est pas une liste complète de tous les produits compatibles.

Centrale de mesure

Produits Compatibilité Note
CR1000 (obsolète)
CR1000 (obsolète)
CR1000 (obsolète)
CR1000 (obsolète)
CR1000 (obsolète)
CR1000 (obsolète)
CR1000 (obsolète)
CR1000 (obsolète)
CR1000 (obsolète)
CR200X (obsolète)
CR216X (obsolète)
CR3000 (obsolète)
CR3000 (obsolète)
CR5000 (obsolète)
CR800 (obsolète)
CR850 (obsolète)
CR9000X (obsolète)

FAQ

Nombre de FAQ au sujet de(s) ENVIROSCAN: 2

  1. To protect itself, the interface will switch off when the supply voltage is above or below these operating voltages:

    • Series 1: 9.6 to 20 Vdc (regulated)
    • Series 2: 4.5 to 15 Vdc (regulated)