Why don’t mixed-array datalogger tables show up in the Data Filer table selection window?

LoggerNet doesn’t know which tables are available in mixed-array dataloggers unless the program is identified by associating it. If no tables show up in the Data Filer table selection window, check that there is a program associated with the datalogger in LoggerNet. This can be done on the Program tab of the LoggerNet Setup screen. Also, verify these two things:

  1. Scheduled collection is enabled (on the Schedule tab of the LoggerNet Setup screen).
  2. FS Area 1 is enabled (and FS Area2 if memory is being specifically allocated to it) for collection. This information is found on the respective tabs in the LoggerNet Setup Screen.