The CS241DM G2 is the second generation of CS241DM, a digital Modbus version of our CS241 Pt-1000 Class A, Back-of-Module Temperature Sensor. This updated sensor features the same best-in-class, surface-mountable temperature sensor with features optimized for bifacial photovoltaic (PV) module performance assessment and soiling. The G2 provides the same measurement accuracy with industrial IEC Class 4 surge protection as its predecessor.
The major change is in the pin layout of the G2's five-pin M12 connector. The new pin assignment conveniently allows you to daisy-chain all Campbell Scientific-recommended sensors installed on a PV string. This improves and simplifies the network topology and reduces cabling costs. We have expanded the operating temperature range, making the sensor suitable for even colder climates. The best part is that all these new features come at no additional cost.
We supply every CS241DM G2 with a NIST-traceable, serialized calibration certificate to meet the performance validation requirements .
Lire la suite
The CS241DM G2 provides PV stakeholders with the most accurate back-of-module temperature, even at long cable lengths, for use in solar PV module power assessment and soiling. Back-of-module temperature is critical for evaluating effective irradiance, soiling, and power conversion, making the G2—which can collect this data—a vital part of any PV performance monitoring system.
The CS241DM G2 consists of a Pt-1000 Class A platinum resistance thermometer (PRT) encased in a specially designed, slim-profile, low-mass aluminum disk. The slim design minimizes sensor impact on bifaciality with less than two percent area coverage on a full-sized cell. The disk shields the PRT from rapid temperature fluctuations while protecting the fragile PRT element during installation. It minimizes heat transfer, which eliminates surface cooling and results in the highest accuracy in measuring, without impacting the temperature of the solar module. The extremely strong disk adhesive has notable thermal properties, including a thermal conductance greater than 600 W/(m2*K). These properties eliminate the need for high-temperature epoxy or tape for additional sensor-to-module bonding, making the installation much easier.
The CS241DM G2 cable has been upgraded to a thin, PFA-jacketed, shielded cable. This upgrade offers the following distinct advantages:
Combining the highest-quality components and thoughtful, coherent CS241DM G2 sensor design results in the highest back-of-module temperature sensor performance. The CS241DM G2 sensor meets or exceeds the thermal properties, accuracy, and uncertainty specifications defined by IEC 61724 for Class A performance and is compliant with IEC 60751, DIN EN 60751 (formerly known as IEC 751).
Veuillez noter : Ce qui suit montre des informations de compatibilité générales. Ce n'est pas une liste complète de tous les produits compatibles.
| Produits | Compatibilité | Note |
|---|---|---|
| SunSentry |
Current CS241DM owners should note the different pinout for the CS241DM G2's five-pin M12 connector. The new pinout is shown on the Let's Go card included with the product and in the manual. While the G2 is compatible with old cables, the newer RS485CBL 24 AWG RS-485 Cable with M12 Five-Pin Connector is recommended for use with the ClimaVue™40 and CS241DM G2.
| Sensor | Precision 1,000 ohm Class A platinum sensing element (Pt-1000) |
| Operating Temperature Range | -50° to +150°C |
| Class A PRT Accuracy | ±(0.15 + 0.002T)°C |
| Temperature Coefficient | TCR = 3,850 ppm/K |
| Long-Term Stability | Maximum Ro drift 0.04% (after 1,000 h at 400°C) |
| Measuring Current | 0.1 to 0.3 mA |
| Uncertainty | The temperature uncertainty is ±0.3° to 0.4°C in the measurement range of -40° to +150°C. |
| Disk Material | Anodized aluminum |
| Disk Diameter | 2.54 cm (1.0 in.) |
| Height | 0.419 cm (0.165 in.) |
| Weight | ~27 g (0.06 lb) with connector and 1 m (3 ft) cable |
Sensor Cable |
|
| Jacket Material | Black semi-gloss PFA, shielded |
| Minimum Bend Radius | 6 mm (0.25 in.) at least 6 mm (0.25 in.) away from sensor disk |
| Cable Diameter | 0.216 cm (0.085 in.) |
| Cable Length | 0.9144 m (3 ft) |
Compliance |
|
| -NOTE- | Compliance information can be found in the Documents section of the web page. |
| Approvals |
|
| EMC Compliance | Conforms to Electromagnetic Compatibility Directive (EMC) |
| RoHS2 | Conforms to the Restriction of Hazardous Substances Directive (RoHS2) |
| Industry Approvals | Compliant with IEC 60751, DIN EN 60751, Industrial Design (IEC Class 4) (formerly known as IEC 751) |
| IP Rating | IP68 rating (self-certified): 1 m submersion for 90 min |
CR6 example program that retrieves information from the input register of four CS241DM G2 sensors, then averages the temperature measurements, and calculates the standard deviation. The Modbus address of the sensors are entered as constants at the beginning of the program; users need to change the Modbus addresses to match their sensors addresses. The CR1000X is programmed similarly.