SI-111SS Infrared Radiometer with Standard Field of View
Determine an Object's Surface Temperature
No physical contact necessary
météorologie : eau : energie : gaz & flux turbulents : infrastructure : terre :

Aperçu

The SI-111SS, manufactured by Apogee, is a precision infrared radiometer that determines the surface temperature of an object without physical contact. It measures both the subject's surface temperature and the sensor-body temperature. A Campbell Scientific data logger uses these measurements to calculate the correct temperature of the subject.

This radiometer features an IP67-rated, marine-grade 316L connector that allows the user to easily swap sensors for recalibration or to replace damaged cables. 

Lire la suite

Avantages et caractéristiques

  • Compatible with most Campbell Scientific data loggers
  • Measures surface temperature continuously in the field
  • Provides road surface, plant canopy, soil surface, snow surface, and water surface temperature measurements
  • Avoids influencing the temperature, providing more accurate measurements
  • Ideal for providing spatial averages
  • Rugged construction—two temperature probes housed in an aluminum body with a germanium window

Images

Description technique

The SI-111SS consists of a thermopile, which measures surface temperature, and a thermistor, which measures sensor body temperature. The two temperature sensors are housed in a rugged aluminum body that contains a germanium window.

Both the thermopile and the thermistor output a millivolt signal that most of our data loggers can measure. The data logger uses the Stefan-Boltzman equation to correct for the effect of sensor body temperature on the target temperature. The corrected readings yield an absolute accuracy of ±0.2°C from -10° to +65°C.

Field of View (FOV)

The SI-111SS has a 22-degree half-angle field-of-view (FOV). The FOV is reported as the half-angle of the apex of the cone formed by the target (cone base) and the detector (cone apex). The target is a circle from which 98% of the radiation viewed by the detector is being emitted.

Spécifications

Sensor Thermopile and thermistor
Input Power 2.5 V excitation (for thermistor)
Response Time < 1 s (to changes in target temperature)
Target Temperature Output Signal 60 μV per °C difference from sensor body
Body Temperature Output Signal 0 to 2500 mV
Optics Germanium lens
Wavelength Range 8 to 14 μm (corresponds to atmospheric window)
Field of View (FOV) 22° half angle
Operating Temperature Range -55° to +80°C
Operating Relative Humidity Range 0 to 100% RH
Cable Description 4.5 m (14.76 ft) twisted, shielded 4-conductor wire with Santoprene casing, ending in pigtails
Absolute Accuracy
  • ±0.2°C (-10° to +65°C)
  • ±0.5°C (-40° to +70°C)
Uniformity
  • ±0.1°C (-10° to +65°C)
  • ±0.3°C (-40° to +70°C)
Repeatability
  • ±0.05°C (-10° to +65°C)
  • ±0.1°C (-40° to +70°C)
Diameter 2.3 cm (0.9 in.)
Length 6 cm (2.4 in.)
Weight 190 g (6.7 oz)

Compatibilité

Veuillez noter : Ce qui suit montre des informations de compatibilité générales. Ce n'est pas une liste complète de tous les produits compatibles.

Centrale de mesure

Produits Compatibilité Note
CR1000 (obsolète)
CR300
CR3000 (obsolète)
CR310
CR350
CR6
CR800 (obsolète)
CR850 (obsolète)

Informations de compatibilité supplémentaires

Mounting

The SI-111SS is often fastened to a CM200-series crossarm, a tripod or tower mast, or a user-supplied pole using a CM230, CM230XL, or CM220 mount. The CM230 and CM230XL are adjustable inclination mounts that allow the SI-111SS to be mounted perpendicular to the target surface when the target surface is on an incline. The CM230XL is similar to the CM230, but the CM230XL places the SI-111SS further from the pole or crossarm. The SI-111 may also be attached directly to a user-supplied camera tripod.


FAQ

Nombre de FAQ au sujet de(s) SI-111SS: 3

Développer toutRéduire tout

  1. En raison de la perte de rayonnement IR, presque tous les instruments à thermopiles ont généralement un décalage négatif. Ce décalage est le plus facilement visible la nuit, quand une petite valeur négative est lue au lieu de zéro. Ce même décalage est présent pendant la journée, mais il n'est pas aussi visible à cause de l'importance du signal solaire.

    Un autre problème commun concerne la mise à niveau d'un instrument. La mise à niveau d'un instrument de thermopile peut entraîner des erreurs dans la composante du faisceau direct car la réponse en cosinus n'est pas correcte. Ces erreurs sont plus notables lorsque le soleil est proche de l'horizon car l'angle est peu profond.

  2. Les informations contenues sur une feuille d'étalonnage diffère entre chaque capteur. Pour certains capteurs, la feuille contient des coefficients nécessaires pour programmer une centrale d'acquisition de données. Pour les autres capteurs, la feuille d'étalonnage est un rapport de réussite/échec.

  3. Cela dépend de l'information contenue dans la feuille d'étalonnage :

    • Si la feuille d'étalonnage contient des coefficients d'étalonnage, Campbell Scientific conserve une copie, et une copie de remplacement peut être demandée.
    • Si la feuille d'étalonnage ne contient pas de coefficients, Campbell Scientific ne conserve pas de copie. Il peut être possible de contacter le fabricant pour une copie.